Radioembolisation of Hepatocellular Carcinoma and Liver Metastases: Imaging Findings Using 90Y Positron Emission Tomography/Computed Tomography and Bremsstrahlung Single Photon Emission Computed Tomography/Computed Tomography
WH Ma, M Law, WY Ho, KK Wong, S Ng, HY Lau, WK Tso
Hong Kong J Radiol 2014;17:140-4
DOI: 10.12809/hkjr1413199
Radioembolisation with Yttrium-90 (90Y)–labelled microspheres administered via the hepatic artery is currently used to treat primary and metastatic non-resectable liver tumours. 90Y is a pure beta-particle emitter and its energetic beta particle has a range of about 4 mm in soft tissue, making it well suited for treatment of bulky tumours. Bremsstrahlung single photon emission computed tomography/computed tomography (SPECT/CT) is commonly performed to assess the biodistribution of 90Y-labelled microspheres post-radioembolisation. Because 90Y emits positrons in a small percentage of its decays, 90Y positron emission tomography/computed tomography (PET/CT) has recently been used for this purpose, yielding higher-resolution visualisation of the distribution of the microspheres. This pictorial review presents, compares, and contrasts Bremsstrahlung SPECT/CT and PET/CT images post-radioembolisation in four patients treated with 90Y-microspheres.